SPD

Surge Protection Devices

DIN-rail surge protection for distribution boards, EV charging, solar installations and equipment protection.

Surge Protection Devices
Representative models

Compare products in this category

Compare model purpose, core specifications and application fit, then continue to the detailed purchasing information.

WSA Surge Protective Device
Surge Protectors

WSA Surge Protective Device

Type 2 protection across twelve models: three discharge ratings in one to four poles, so a single-phase consumer unit and a three-phase board with neutral are served from the same platform. A window on each module turns red when the module has reached the end of its life and needs replacing.

View specifications →
WSA+N Surge Protective Device
Surge Protectors

WSA+N Surge Protective Device

The T/T arrangement of the WSA platform. The same three discharge ratings are supplied with a dedicated N-PE module alongside the phase modules, for installations where the neutral is not bonded to earth at the board. Six models: 1P+N on two modules, 3P+N on four.

View specifications →
WSP Mini Surge Protective Device
Surge Protectors

WSP Mini Surge Protective Device

The same Type 2 duty in a single module instead of two, for boards where the spare ways are the constraint. The protection cartridges are pluggable, so a module that has reached the end of its life is exchanged without disturbing the wiring, and a green window plus a remote alarm contact both report the fault.

View specifications →
WSP+N Mini Surge Protective Device
Surge Protectors

WSP+N Mini Surge Protective Device

The T/T version of the mini range, protecting L-N and N-PE from one module. Each rating is supplied in two connection formats — busbar and wire — so it drops into a busbar-fed board or one wired module by module without changing the device.

View specifications →
WST Surge Protective Device
Surge Protectors

WST Surge Protective Device

Type 1+2 protection for the origin of an installation, where a device has to survive a direct lightning current rather than only the surge that follows it. Rated 12.5kA of 10/350us impulse current per pole alongside the 8/20us duty a Type 2 handles, in one to four poles, so the service entrance and the boards downstream can be protected on one platform.

View specifications →
WST-N Surge Protective Device
Surge Protectors

WST-N Surge Protective Device

The Type 1+2 range configured for a T/T system, where the neutral has to be protected against the earth rather than treated as a reference. A gas discharge tube sits in the N-PE path and the remaining poles carry the varistor modules, so a 1P+N device is one tube and one varistor rather than two of a kind.

View specifications →
Selection overview

Core specification range

CapabilityType 1, Type 1+2 and Type 2
CapabilityAC and DC systems
CapabilityConsumer-unit configurations
StandardsIEC / EN 61643
CustomisationLogo · Packaging · Documentation